8D Scan Pro · Public sample

5 Whys with AI: root cause analysis example

Loose bolted joint: a sample case for suppliers preparing their own root cause analyses and customers examining supplier analyses.

How does the 5 Whys method work with AI?

In 5 Whys, each answer is challenged with another why question until a testable cause and a suitable safeguard emerge. Five questions are a guide, not a rigid requirement. Occurrence and non-detection are investigated separately. AI can suggest possible chains; professional verification remains with the team.

  1. Describe the problem and known facts: what was detected, where, when and to what extent?
  2. Connect each why answer to the previous statement and examine alternative explanations.
  3. Test hypotheses using measurements, experiments or robust circumstantial evidence; document uncertainty and verify corrective action effectiveness in D6.

The example below is editorially prepared and entirely fictional, not a real AI customer report. Your own analyses with AI suggestions and PDF export are included in Pro and the active pilot month.

Problem / defect detection

Fictional sample case: customer incoming inspection finds loose bolted joints on 8 of 200 brackets. Required tightening torque: 12 ± 1 Nm. All details and evidence are invented for illustration only.

No customer data. Evidence marked as supported is also fictional. AI suggestions always start as hypotheses; a method alone does not prove a cause. Corrective action effectiveness must be verified separately in D6.

Occurrence cause

  1. 1. Why?

    The joint is loose because tightening torque was too low.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: station delivered 8 Nm in the comparison test; at 12 Nm no loose joint occurred.
    Verification / next steps
    Verify the causal chain experimentally; validate corrective actions in D6 afterwards.
  2. 2. Why?

    Torque was too low because the driver used another variant's program.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: station log shows program B at 8 Nm instead of program A at 12 Nm.
    Verification / next steps
    Verify the causal chain experimentally; validate corrective actions in D6 afterwards.
  3. 3. Why?

    The wrong program remained active because manual program selection was not changed during the variant changeover.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: repeating the changeover from B to A without switching reproduces the defect.
    Verification / next steps
    Verify the causal chain experimentally; validate corrective actions in D6 afterwards.
  4. 4. Why?

    The changeover was not safeguarded because part identification was not linked to the driver program.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: station accepts variant A with program B; no interlock signal.
    Verification / next steps
    Verify the causal chain experimentally; validate corrective actions in D6 afterwards.
  5. 5. Why?

    The safeguard was missing because variant mix-up was not considered in the process FMEA and station approval.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: approval documents contain no test of the wrong-program / correct-part combination.
    Verification / next steps
    Verify the causal chain experimentally; validate corrective actions in D6 afterwards.

Detection cause

  1. 1. Why?

    The defect escaped because final inspection checked the bolted joint visually only.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: eight loose joints pass the repeated visual inspection.
    Verification / next steps
    Test inspection logic with deliberate defects and good parts; confirm effectiveness in D6.
  2. 2. Why?

    Visual inspection found nothing because insufficient torque has no visible indication.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: good and defective parts look alike; torque records differ.
    Verification / next steps
    Test inspection logic with deliberate defects and good parts; confirm effectiveness in D6.
  3. 3. Why?

    There was no alarm because inspection logic checked cycle completion, not variant-specific torque.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: an 8 Nm cycle receives an OK signal for variant A.
    Verification / next steps
    Test inspection logic with deliberate defects and good parts; confirm effectiveness in D6.
  4. 4. Why?

    Inspection logic was insufficient because the control plan did not require checking the program-to-part assignment.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: inspection plan specifies cycle OK and visual inspection only.
    Verification / next steps
    Test inspection logic with deliberate defects and good parts; confirm effectiveness in D6.
  5. 5. Why?

    The gap persisted because inspection effectiveness was not validated using deliberately defective parts.

    Supported by sample evidence

    Evidence (fictional)
    Sample evidence: inspection approval contains no challenge test with incorrect torque.
    Verification / next steps
    Test inspection logic with deliberate defects and good parts; confirm effectiveness in D6.

Create your own 5 Whys analysis with AI

Included in Pro and during the active pilot month: 5 Whys and Ishikawa with AI hypotheses, evidence, status and PDF export.